• LED hazardous and safe area sightglass light fittings

LED hazardous and safe area sightglass light fittings

  • Product Code: LED hazardous and Safe area

We closely observes the development of the LED technology for years and may therefore present a wide range of innovative sightglass light fittings for applications either in hazardous or in safe ares. The LED versions offer the following advantages:

- UV-free and cold light output

- Extremely long life span (ca 20'000–40'000 operating hours), thus making periodic maintenance unnecessary

- Very high lighting power at small consumption

- Suitable for continuous operation

- Housings and fixations from stainless steel or cast aluminium alloy, depending on application

- Light fittings can be combined with window wipers or spraying devices, depending on type and application


Application:

- On sightglasses to DIN 28120 from DN 25

- On sightglasses to DIN 28121 from DN 40

- On screwed sightglasses similar to DIN 11851 from DN 32

- On pipeline flow indicators (in-line sightglasses)

- On metal fused sightglasses


Enclosure protection degree:

IP67, dust tight and protected against the effects of temporary immersion


Short overview on available types for applications in safe areas:


miniLUX Micro-LED, series MVLR

- Entirely in stainless steel

- Terminal voltage 22–26 V AC / DC

- Power ca. 2 W

- Available for continuous, momentary or "ON-OFF" operation

- Fixation by means of collar flange or tilting hinge

DETAILS


miniLUX, series BKVLR LED

- Entirely in stainless steel

- Terminal voltage 24 V AC / DC

- Power 1, 2 or 4 W

- Available for continuous, momentary or "ON-OFF" operation

- Fixation by means of collar flange or tilting hinge

- Particularly recommended for use on pipeline flow indicators

DETAILS


miniLUX, series KLR PowerLED

- Entirely in stainless steel

- Terminal voltage 24 V AC / DC or 230–240 V AC

- Power: 7 W

- "Spot" version (small output angle) or in the "flood" version (wide output angle)

- Available for continuous, momentary or "ON-OFF" operation

- Fixation by means of collar flange or tilting hinge

DETAILS


metaLUX, series HL, HLM or HLMR LED

- Housings from cast aluminium alloy (HL LED), cast aluminium alloy painted (HLM LED) or stainless steel (HLMR LED)

- Terminal voltage 24 V AC / DC

- Power ca. 2–6 W, depending on type

- Available for continuous, momentary or "ON-OFF" operation

- For direct mounting onto sightglasses to DIN 28120 / 28121 and similar to DIN 11851

DETAILS


CHEMLUX, series KL PowerLED

- Terminal voltage 24 V AC / DC or 230–240 V AC

- Power: 7 W / light output of ~980 Lumen

- Fixation by means of collar flange, side feet or mounting bracket

DETAILS


CHEMLUX, series FHL PowerLED

- Terminal voltage 24 V AC / DC or 230–240 V AC

- Power: 7 W / light output of ~980 Lumen

- Available for continuous, momentary or "ON-OFF" operation

- Fixation by means of collar flange, side feet or mounting bracket

DETAILS


Short overview on available types for applications in hazardous areas:


CHEMLUX, series KEL PowerLED / FKEL PowerLED

- Terminal voltage 24 V AC / DC or 230–240 V AC

- Power: 7 W / light output of ~980 Lumen

- (Ex)-classification: Ex d or de op is IIC T6 Gb, Ex tb IIIC T80°C Db IP65/67, Ex II G + D

- ATEX equipment protection level (EPL): Gb (zones 1 and 2) and Db (zones 21 and 22)

- Fixation by means of collar flange, side feet or mounting bracket

DETAILS


CHEMLUX, series HEL PowerLED / FHEL PowerLED

- Terminal voltage 24 V AC / DC or 230–240 V AC

- Power: 7 W / light output of ~980 Lumen

- (Ex)-classification: Ex d or de op is IIC T6 Gb, Ex tb IIIC T80°C Db IP67, Ex II G + D

- ATEX equipment protection level (EPL): Gb (zones 1 and 2) and Db (zones 21 and 22)

- Available for continuous, momentary or "ON-OFF" operation

- Fixation by means of collar flange, side feet or mounting bracket

DETAILS


EdelLUX, series EdelEx LED / PowerLED

- Entirely in stainless steel

- Terminal voltage: 24 V AC / DC (LED) or 24 V AC / DC or 230–240 V AC (PowerLED)

- Power: 2 (LED) or 7 (PowerLED) W

- (Ex)-classification: Ex d IIC T6 Gb, Ex t IIIC T80°C Db IP67, Ex II G + D (LED) or Ex d op is IIC T6 Gb, Ex tb IIIC T80"C Db, Ex II G + D

- ATEX equipment protection level (EPL): Gb (zones 1 and 2) and Db (zones 21 and 22)

- Available for continuous operation or with external timer

- Fixation by means of collar flange or tilting hinge

DETAILS


Tags: LED lighting, hazardous areas, safe area lighting, sightglass fittings, industrial lighting, explosion-proof, ATEX, IECEx, John Moncrieff, supplier, manufacturing, engineering, quality, reliability, safety